6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
Ul rating for concrete walls.
Fire ratings for such construction systems are determined from methodologies established in astm e 119 which sets the intensity of the fire the size of the specimen and the criteria for determining the end point of the test.
These listings are short summaries to serve as a.
The ul certification mark on fire resistant products systems and assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market requirements.
It is a key differentiator for products within the exterior wall assembly market.
Mineral and fiber boards a category for a group of ul certified products.
Using this standard extensive testing over many years.
Membrane penetration an opening made through one side wall floor or ceiling membrane of a fire resistance rated assembly.
For finishes on the fire exposed side of the wall a time from table 8 is assigned to the finish.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
Fire resistance rating or fire rating is defined as the duration of time that an assembly roof floor beam wall or column can endure a standard fire as defined in astm e 119 3.
Fire resistance rating of single layer concrete walls floors and roofs multiple layer walls floors and roofs there are several methods such as graphical numerical and analytical solutions provided by aci 216 1m 7 that used to determine the fire resistance of walls floors and roofs composed of two or more layers of different types.
Fire endurance of structures figure 5 shows the effect of fire on the resistance of a simply supported reinforced concrete.
The result t ef is then added to the concrete masonry wall equivalent thickness t e and used in table 1 to determine the wall s fire resistance rating i e the equivalent thickness of concrete masonry assemblies t ea t e t ef.
Structural function or both.
Insulating concrete nonstructural concrete with a unit weight less than 60 pcf.
The complete description of the products.
Westbrook block is a proud producer of underwriters laboratories ul approved fire rated cmu in both light weight and normal weight densities in 2 3 and 4 hour configurations.
These blocks while allowing for safe means of egress and fire rating should no longer be looked at as just normal grey cmu.